Verified calculation capability
Compute MOSFET conduction loss from I, Rds(on), current_basis (dc / on-interval RMS / full-cycle MOSFET RMS), and optional Rds(Tj) via linear α or datasheet ratio. · Electrical · Mosfet
Capability ID electrical.mosfet.conduction_loss · version 1.2.2
On-interval RMS
P = I_on,rms² × Rds(on) × DP = I_rms² × Rds(on)VDS estimate = I × Rds_TjRds(Tj) = Rds(Tref) × (1 + α × (Tj − Tref))Rds(Tj) = Rds(Tref) × rds_ratioCanonical symbols for this capability. Agent schemas remain the contract.
| Symbol | Quantity | Unit | Role |
|---|---|---|---|
I | Current in amperes. Meaning depends on current_basis: DC amps, RMS during the MOSFET ON interval, or full-cycle MOSFET RMS. | — | input / output |
Rds | On-resistance Rds(on) (Ω) at Tref (usually 25 °C). Use temperature_model to scale to Tj. | — | input / output |
D | Duty cycle fraction in (0, 1]. Used only when current_basis=on_interval_rms. Ignored (warning DUTY_NOT_APPLICABLE) for dc and full_cycle_rms. Default 1. | — | input / output |
current_basis | How I is defined. Required. dc: continuous current, P=I²·Rds_Tj, D=1. on_interval_rms: I is RMS while the FET is on, P=I²·Rds_Tj·D. full_cycle_rms: I is MOSFET RMS over the switching period, P=I²·Rds_Tj (do not multiply by D). The engine will not infer a waveform factor. | — | input / output |
temperature_model | Rds(Tj) correction. none (default): use Rds as entered. linear: Rds_Tj=Rds·(1+α·(Tj−Tref)). ratio: Rds_Tj=Rds·rds_ratio. Omitting temperature_model infers ratio if rds_ratio is set (ratio wins even when Tj_C or alpha_per_C is also present), else linear if Tj_C or alpha_per_C is set, else none. | — | input / output |
Tj | Junction temperature (°C). Required for temperature_model=linear. | °C | input / output |
Tref | Rds reference temperature (°C). Default 25. | °C | input / output |
alpha_per | Linear temperature coefficient (1/°C). Default 0.006 when linear and omitted — a Si MOSFET planning default, not a datasheet value. | °C | input / output |
rds_ratio | Normalized Rds(Tj)/Rds(Tref) from the datasheet curve. Required for temperature_model=ratio. | — | input / output |
P | Conduction loss at Rds_Tj (W). P=I²·Rds_Tj·D when current_basis=on_interval_rms; P=I²·Rds_Tj otherwise. | W | output |
V_drop | Resistive voltage drop at the entered current using Rds_Tj: I·Rds_Tj (V). | — | output |
Rds_Tj | Rds used in P_W (Ω). Equals Rds when temperature_model=none. | — | output |
P_W_ref | Conduction loss at entered Rds / Tref (W). Present when a temperature model is applied. | — | output |
V_drop_ref | I·Rds at Tref (V). Present when a temperature model is applied. | — | output |
Declared scope for this capability. Do not use it outside this domain.
Assumptions
One numerical check. The calculator page holds worked steps and FAQ.
current_basis=dc, I=10, Rds=0.05, rds_ratio=1.44 → P_W=7.2, Rds_Tj=0.072, P_W_ref=5
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.
Human page, REST, and MCP share the same engine and calculation_version.
Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json
and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 12/12.
Declared calculation modes for this capability.
dcon_interval_rmsfull_cycle_rmsHuman-readable sources plus CVP reference evidence classes.
Sources
Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior
Inspect this capability via same-origin MCP, then call execute_calculation.
curl -sS -X POST 'https://www.calculatorx.com/mcp' \
-H 'Content-Type: application/json' \
-H 'MCP-Protocol-Version: 2026-07-28' \
-H 'Mcp-Method: tools/call' \
-H 'Mcp-Name: inspect_capability' \
-d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.mosfet.conduction_loss"}}}'
Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.2.2) when reproducibility matters. Full protocol notes: MCP docs.