Home Developers Capabilities Amps to kW

Verified calculation capability

Amps to kW Calculation Capability

Convert current and voltage to real power in kW (or reverse) for DC, single-phase AC, and balanced three-phase L-L. · Electrical

Capability ID electrical.amps_to_kw · version 1.4.3

Model

DC

Inputs / Outputs

Canonical symbols for this capability. Agent schemas remain the contract.

SymbolQuantityUnitRole
formulaoutput
api_versionoutput
api_contract_versionoutput
spec_versionoutput
pageCanonical calculator page URLoutput
linksoutput

Assumptions / Validity

Declared scope for this capability. Do not use it outside this domain.

Assumptions

Not supported

Example

One numerical check. The calculator page holds worked steps and FAQ.

20 A, 400 V, PF 0.9, AC 3φ → 12.471 kW

Open this example in the calculator

Trust

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.

CVP
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance· View Manifest · CVP overview · Specification
Assurance
Engineering
Declared partition coverage
PASS · 10/10 declared partitions (a-kw-dc, a-kw-ac_single, a-kw-ac_three, kw-a-dc, kw-a-ac_single, kw-a-ac_three, invalid-domain, round-trip, metamorphic, near-singularity)
Calculation version
1.4.3
Verification
16/16 calculation tests · 8/8 legacy golden · 3/3 legacy boundary · 5/5 legacy property
Production surface contract
34/34
Versions
Calculation 1.4.3 · CVP protocol 1.0.0-proposed · Evidence 2026-09-10.evidence-semantics
Verification revision
2026-09-10.evidence-semantics · 5/5 property · digest 1fc8b58b8507
Reference
O1 model · O2 expected_values · O2 numerical_behavior
Numerical scope
≤2 ULP vs this O2 module on the published golden, near-singularity boundary, round-trip, and metamorphic vectors. Computational fidelity: ULP vs O2. Engineering interpretation: exact deterministic algebraic model; measurement uncertainty is outside calculator scope. Not a whole-domain guarantee (overflow, denormals, or unlisted V→0 neighborhoods). O2 shares Node/V8 binary64 with the IUT; O3 is not required this wave.
Interfaces
PASS · UI (SSR) / REST / MCP
ui-ssr is query-result HTML, not a live browser session.
CVP suite
7/7 golden · 4/4 CVP boundary · 6/6 invalid · 5/5 property · 6/6 metamorphic · 6/6 round-trip · 1/1 cross-interface · 2/2 cross-calculator · 34/34 CVP contract
Supplemental domain review
Internal · Pass · electrical-engineer
Named expert review
Not performed
Version lock
Supported (409 VERSION_MISMATCH)
Artifact consistency
Build verified · 1.4.3 (workspace artifacts agree)
Review-policy tier
Internal engineering review — catalog token expert_verified; supplemental; not CVP status
This calculator CURRENT · Public schema 1.4.3 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

Call this capability

Human page, REST, and MCP share the same engine and calculation_version. Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 34/34.

Tool id
amps-to-kw
Engine
amps-kw
REST
POST /api/v1/calc/amps-to-kw
MCP
execute_calculation with capability_id: "electrical.amps_to_kw"
Agent input schema
Canonical (MCP / Agent)
Output schema
JSON Schema (latest)
Versioned input schema
Immutable pin (1.4.3)
Versioned output schema
Immutable pin (1.4.3)

Operations

Declared calculation modes for this capability.

References

Human-readable sources plus CVP reference evidence classes.

Sources

Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior

Try with an agent

Inspect this capability via same-origin MCP, then call execute_calculation.

curl -sS -X POST 'https://www.calculatorx.com/mcp' \
  -H 'Content-Type: application/json' \
  -H 'MCP-Protocol-Version: 2026-07-28' \
  -H 'Mcp-Method: tools/call' \
  -H 'Mcp-Name: inspect_capability' \
  -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.amps_to_kw"}}}'

Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.4.3) when reproducibility matters. Full protocol notes: MCP docs.