Machine-checked verification for calculation version 1.4.2 · tier internally_reviewed

CVP: CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · core energy calculation (W × h / 1000 → kWh)· CVP VERIFIED covers the core energy calculation E(kWh)=W×h/1000. Daily month/year figures are UI projections (30-day month, 365-day year), not engine outputs. · Protocol · Schema · Production report

Declared partition coverage
PASS · 3/3 declared partitions (nominal-positive, zero, invalid-domain)
Versions
Calculation 1.4.2 · CVP protocol 1.0.0-proposed · Evidence 2026-09-13.negative-input-contract
Verification revision
2026-09-13.negative-input-contract · 4/4 property · digest 9f36849cd3cd

Verification

Legacy regression suite: 16/16 calculation tests · Production surface contract 4/4

Three distinct suites: educational examples on the calculator page, this legacy regression count (16/16 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.4.2 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-09-13.negative-input-contract. Calculation version 1.4.2. CVP 1.0.0-proposed. 2/2 golden · 3/3 CVP boundary · 5/5 invalid · 4/4 property · 2/2 cross-interface · 4/4 CVP contract. digest 9f36849cd3cd.

  • Golden (oracle-backed) 2 / 2
  • CVP boundary 3 / 3
  • Invalid input 5 / 5
  • Property 4 / 4
  • Cross-interface 2 / 2
  • CVP contract 4 / 4
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session.
  • Verified scope core energy calculation (W × h / 1000 → kWh)
  • Assurance Engineering
  • Deferred UI daily/month/year projections (×30 / ×365)
  • release artifacts aligned PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS

Fingerprint sha256:12b8656c5419669724d3a3f6bedfd69f11c8f1e6df1e20e231487fb250072916

Input schema sha256:4fbea79f291b0be2d402bcdf35e1ee32958364497986406299f9bc995d16ad71 · Output schema sha256:513207640dd3f6145f0da67434085aa12ebf3bc9a84d9250d53dda64ead66e47 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
energy-consumption
Engine
energy
Engine build
2026-09-13
Evidence core
2026-09-13T14:29:59.920Z
Rendered
2026-09-16T22:03:43.701Z
Last reviewed
2026-09-13

Assumptions

  • Constant power over the stated hours.
  • Month = 30 days, year = 365 days in daily UI projections (presentation-only).
  • User converts kW→W when needed.
  • W ≥ 0 and hours ≥ 0 (consumption, not signed energy flow).

Limitations

  • Assumes constant power over the stated hours
  • W and hours must be ≥ 0 (VALUE_MUST_BE_NON_NEGATIVE)
  • UI daily month/year projections are presentation-only; engine returns period kWh

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Legacy published checks

Golden and boundary cases from the legacy Evidence JSON. CVP property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the Manifest — including SKIP when a suite has no vectors.

IDKindStatusDetail
1500W-3hgoldenpassExpected 4.5 · Actual 4.5
9W-8hgoldenpassExpected 0.072 · Actual 0.072
1000W-1hgoldenpassExpected 1 · Actual 1
60W-5hgoldenpassExpected 0.3 · Actual 0.3
linear-2x-WgoldenpassExpected 9 · Actual 9
linear-2x-hgoldenpassExpected 9 · Actual 9
soft-zero-WgoldenpassExpected 0 · Actual 0
soft-zero-hgoldenpassExpected 0 · Actual 0
neg-WboundarypassExpected VALUE_MUST_BE_NON_NEGATIVE · Actual VALUE_MUST_BE_NON_NEGATIVE
neg-hoursboundarypassExpected VALUE_MUST_BE_NON_NEGATIVE · Actual VALUE_MUST_BE_NON_NEGATIVE
2000W-24hgoldenpassExpected 48 · Actual 48
missing-WboundarypassExpected MISSING_REQUIRED_INPUT · Actual MISSING_REQUIRED_INPUT
property-kwhpropertypassE = P·t / 1000
property-linear-powerpropertypassE(2P)=2E(P)
property-linear-timepropertypassE(2t)=2E(t)
property-defaultpropertypass1500 W × 3 h