Home Developers Capabilities Diode equation

Verified calculation capability

Diode equation Calculation Capability

Shockley diode Id↔Vd. Canonical T_K; UI/query alias T_C. Defaults: mode=id, n=1, T_K=300. Inverse domain Id > -Is. · Electrical · Diode

Capability ID electrical.diode.equation · version 1.1.0

Model

Shockley

Solve modes: id · vd

Inputs / Outputs

Canonical symbols for this capability. Agent schemas remain the contract.

SymbolQuantityUnitRole
VdDiode voltage in volts. Required when mode=id (default).input / output
IdDiode current in amperes. Required when mode=vd. Shockley inverse domain: Id > -Is (includes Id=0 and reverse branch).input / output
IsSaturation current at the selected junction temperature T. Not derived as Is(T) from a reference-temperature value.input
nIdeality factor. Default 1.input
TJunction temperature in kelvin. Canonical REST/MCP input. Default 300.Kinput
TOptional Celsius alias for junction temperature. UI/query accept T_C; canonical schema is T_K. If both are sent, T_K wins.°Cinput
Vtoutput

Assumptions / Validity

Declared scope for this capability. Do not use it outside this domain.

Assumptions

Not supported

Example

One numerical check. The calculator page holds worked steps and FAQ.

Vd=0.7 Is=1e-12 n=1 T_K=300 → Id≈0.574755 A

Open this example in the calculator

Trust

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.

CVP
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance· View Manifest · CVP overview · Specification
Assurance
Engineering
Declared partition coverage
PASS · 5/5 declared partitions (fwd-id, inv-vd, reverse-bias, small-x, invalid-domain)
Calculation version
1.1.0
Verification
15/15 calculation tests · 5/5 legacy golden · 6/6 legacy boundary · 4/4 legacy property
Production surface contract
4/4
Versions
Calculation 1.1.0 · CVP protocol 1.0.0-proposed · Evidence 2026-09-13.shockley-inverse-trust.2
Verification revision
2026-09-13.shockley-inverse-trust.2 · 2/2 property · digest 4899855db55a
Reference
O1 model · O2 expected_values · O2 numerical_behavior
Interfaces
PASS · UI (SSR) / REST / MCP
ui-ssr is query-result HTML, not a live browser session.
CVP suite
6/6 golden · 10/10 CVP boundary · 11/11 invalid · 2/2 property · 8/8 round-trip · 4/4 cross-interface · 4/4 CVP contract
Supplemental domain review
Internal · Pass · electrical-engineer
Named expert review
Not performed
Version lock
Supported (409 VERSION_MISMATCH)
Artifact consistency
Build verified · 1.1.0 (workspace artifacts agree)
Review-policy tier
Internally reviewed — catalog token internally_reviewed; supplemental; not CVP status
This calculator CURRENT · Public schema 1.1.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

Call this capability

Human page, REST, and MCP share the same engine and calculation_version. Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 4/4.

Tool id
diode-equation
Engine
diode-equation
REST
POST /api/v1/calc/diode-equation
MCP
execute_calculation with capability_id: "electrical.diode.equation"
Agent input schema
Canonical (MCP / Agent)
Output schema
JSON Schema (latest)
Versioned input schema
Immutable pin (1.1.0)
Versioned output schema
Immutable pin (1.1.0)

References

Human-readable sources plus CVP reference evidence classes.

Sources

Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior

Try with an agent

Inspect this capability via same-origin MCP, then call execute_calculation.

curl -sS -X POST 'https://www.calculatorx.com/mcp' \
  -H 'Content-Type: application/json' \
  -H 'MCP-Protocol-Version: 2026-07-28' \
  -H 'Mcp-Method: tools/call' \
  -H 'Mcp-Name: inspect_capability' \
  -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.diode.equation"}}}'

Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.1.0) when reproducibility matters. Full protocol notes: MCP docs.