Home Developers Capabilities Battery runtime with temperature

Verified calculation capability

Battery runtime with temperature Calculation Capability

Constant-load battery runtime with a generic cold-derating temperature capacity factor about 25 °C (extends Battery Runtime base: watts load-side / amps battery-side). Planning model — not chemistry. · Electrical · Battery

Capability ID electrical.battery.runtime_temp · version 1.2.1

Model

Temperature factor (default cold-only)

Inputs / Outputs

Canonical symbols for this capability. Agent schemas remain the contract.

SymbolQuantityUnitRole
t_hEstimated runtime (hours) at T_Coutput
t_dEstimated runtime (days = t_h/24)output
E_WhUsable energy in Wh after temperature factor. Watts: Ah_eff·V·DoD·η. Amps: Ah_eff·V·DoD.output
temp_factorTemperature capacity factor f_T (same as temperature.capacity_factor)output
TEcho of input temperature (°C)°Coutput
k_TPlanning coefficient used (/°C); default 0.006 — not manufacturer validatedoutput
capacity_Ah_effAh × f_T after temperature deratingoutput
temperatureoutput

Assumptions / Validity

Declared scope for this capability. Do not use it outside this domain.

Assumptions

Example

One numerical check. The calculator page holds worked steps and FAQ.

10 Ah · 12 V · 20 W · T=0 °C · k_T=0.006 → f_T=0.85 · t=5.1 h (−0.9 h vs 25 °C)

Open this example in the calculator

Trust

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance. Computational verification is defined by CVP. Supplemental domain review (internal) and named expert review are defined by the Review policy and do not by themselves determine CVP conformance.

CVP
CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance· View Manifest · CVP overview · Specification
Assurance
Engineering
Declared partition coverage
PASS · 6/6 declared partitions (watts, amps, generic-cold, custom-symmetric, clamped-regime, invalid-domain)
Calculation version
1.2.1
Verification
31/31 calculation tests · 5/5 legacy golden · 10/10 legacy boundary · 16/16 legacy property
Production surface contract
4/4
Versions
Calculation 1.2.1 · CVP protocol 1.0.0-proposed · Evidence 2026-09-11.xcal-meta-derived
Verification revision
2026-09-11.xcal-meta-derived · 16/16 property · digest 742a9a7e3a3b
Reference
O1 model · O2 expected_values · O2 numerical_behavior
Interfaces
PASS · UI (SSR) / REST / MCP
ui-ssr is query-result HTML, not a live browser session.
CVP suite
4/4 golden · 8/8 CVP boundary · 5/5 invalid · 16/16 property · 3/3 metamorphic · 2/2 cross-interface · 2/2 cross-calculator · 4/4 CVP contract
Supplemental domain review
Internal · Pass · electrical-engineer · CalculatorX electrical review · 2026-08-12
Named expert review
Not performed
Version lock
Supported (409 VERSION_MISMATCH)
Artifact consistency
Build verified · 1.2.1 (workspace artifacts agree)
Review-policy tier
Internally reviewed — catalog token internally_reviewed; supplemental; not CVP status
This calculator CURRENT · Public schema 1.2.1 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

Call this capability

Human page, REST, and MCP share the same engine and calculation_version. Build verified hashes workspace artifacts only. After deploy, attest:production GETs canonical URLs twice — the public/cached view an Agent actually hits, and origin — including every /capabilities/{id} HTML page. Public Capability HTML version must match catalog before production attestation passes. Live Trust rows above fetch /.well-known/calculatorx-production-attestation.json and the output schema const. Build hashes: release integrity. That proves currently published page / engine / schema / evidence / MCP agree — not that a historical version is independently immutable. Reference Calculation Standard — Production surface contract 4/4.

Tool id
battery-runtime-temp
Engine
battery-runtime-temp
REST
POST /api/v1/calc/battery-runtime-temp
MCP
execute_calculation with capability_id: "electrical.battery.runtime_temp"
Agent input schema
Canonical (MCP / Agent)
Output schema
JSON Schema (latest)
Versioned input schema
Immutable pin (1.2.1)
Versioned output schema
Immutable pin (1.2.1)

Operations

Declared calculation modes for this capability.

References

Human-readable sources plus CVP reference evidence classes.

Sources

Reference evidence classes: O1 model · O2 expected_values · O2 numerical_behavior

Try with an agent

Inspect this capability via same-origin MCP, then call execute_calculation.

curl -sS -X POST 'https://www.calculatorx.com/mcp' \
  -H 'Content-Type: application/json' \
  -H 'MCP-Protocol-Version: 2026-07-28' \
  -H 'Mcp-Method: tools/call' \
  -H 'Mcp-Name: inspect_capability' \
  -d '{"jsonrpc":"2.0","id":1,"method":"tools/call","params":{"name":"inspect_capability","arguments":{"capability_id":"electrical.battery.runtime_temp"}}}'

Inspect the trust tier and required assurance level before execution. Pin calculation_version (1.2.1) when reproducibility matters. Full protocol notes: MCP docs.